Product Features
 
CUSTOM DUAL DISPLAY LCD
Primary and secondary displays are available for simultaneous display of Conductivity and Temperature values. Allows instantaneous viewing of measured readings and setup configurations.
 
EASY PUSH-BUTTON OPERATION
Simply calibrate or adjust setup configuration with just a few touches of the buttons. Push-button offset adjustment makes calibration simple in the conductivity models.
 
TEMPERATURE COMPENSATION
Compensates variance in the measured readings due to temperature fluctuations, either Automatically (with Pt 100) or Manually (Process and Calibration temperatures can be set separately).
 
PANEL OR WALL MOUNT, IP65 WEATHERPROOF HOUSING
Meters can be mounted on the wall or in a control panel. In addition, the IP65 rated housing allows the meter to be installed outdoors or indoors. Mounting accessories are included for both types of mounting.
 
EASY TO USE CONTROLLER FUNCTIONS
Two switching contacts acting as set-point relays simplify your task of controlling various processes. Separately adjustable high and low set-point hysteresis ensure chatter-free signal at the set-points.
 
ADVANCED FEATURES FOR BETTER CONTROL
Ability to set a time-delay up to 2000 seconds eliminates unneeded control and prevents false alarms, making it ideal for industrial environments.
 
BACK-LIT UV LIGHT PROTECTED LCD
Back-lit display ensures easy reading even in the dark. UV light protection minimises adverse effect of exposure to sunlight.
 
 
Specifications                                           
Product Specification
Description
Conductivity range
*(R1): 0-2 µS/cm
R1 (R2): 0-20 µS/cm
R2 (R3): 0-200 µS/cm
R3 (R4): 0-2000 µS/cm
R4 (R5): 0-20 mS/cm
R5 (R6): 0-200 mS/cm
Resolution
0.001 µS/cm
0.01 µS/cm
0.1 µS/cm
1 µS/cm
0.01 mS/cm
0.1 mS/cm
Accuracy
±1% of full scale reading in respective range
Temperature
-10 °C to 125 °C
(14 °F to 257 °F)
Resolution
0.1 °C
(0.1 °F)
Relative Accuracy
±0.5 °C
(±0.9 °F)
Sensor
Pt100 / Pt1000 (3 wire / 2 wire) (selectable)
Temperature Compensation
Auto/Manual (reference at 25 °C)
Cell Constant
User-selectable (0.10 to 10.00)
Temperature Coefficient
0 to 10% (selectable)
Normalisation Temperature
25 °C
Controller Function
Limit Control
Relay Operating Parameters
LO (Relay active when measured value < set point)
HI (Relay active when measured value > set point
Time Delay
0 to 2000 seconds
Switching Conductivity Hysteresis
0 to 10% of full scale
Contact Output
2 SPST relay
Switching Voltage/Current Power
Max 250VAC/Max 3A/MAX 600 VA
Display
Dual Display Custom LCD
Backlight
On/Off selectable
Power Requirements
110 or 220 VAC to 9 V DC Adapter
Dimension
96 x 96 x 66 mm (3.78 x 3.78 x 2.6 inch)
Weight
210 g